XT5N 400 Ekip Dip LS/I 400 3p FF UL ABB Circuit Breaker 400A 600V 3Poles

Please call 800-717-6475 to check current stock and pricing.

XT5X 400 BREAKING PART 3p F F ABB Circuit Breaker, 600 VAC/VDC, 35 kA @ 480 VAC Interrupt, XT5 Frame, Ekip DIP LS/I Trip, 3 Pole, Terminals Connection, Fixed Mounting, 5.51 in W x 4.07 in D x 8.07 in H Dimensions

SKU: ABB XT5N 400 Ekip Dip LS/I 400 3p FF UL Category: Brand:

Description

ABB XT5N 400 Ekip Dip LS/I 400 3p FF UL Circuit Breaker, 600 VAC/VDC, 35 kA @ 480 VAC Interrupt, 3 Poles, Ekip DIP LS/I Trip
The ABB ABB XT5N 400 Ekip Dip LS/I 400 3p FF UL is a Molded Case Circuit Breaker from the SACE Tmax XT family. This 3-pole breaker is rated for 400 amps and 600 volts, with an interrupting rating of 25kA at 480V. It features a bolt-on connection and solid state protection with LSI trip functions.

Specifications
Specifications
Manufacturer Part Number XT5NU340AEFF000XXX
Manufacturer ABB
Product Series Tmax XT
Family Series ABB Circuit Breakers, Tmax XT Series
Description XT5N 400 Ekip Dip LS/I 400 3p FF UL
Poles 3
Current Rating 400 A
Max Voltage 600 VAC
Mounting Panel
✔ Category: Circuit Breaker
✔ Subcategory: Molded Case
✔ Family: SACE Tmax XT
✔ Voltage: 600
✔ Amperage: 400
✔ Poles: 3
✔ AIC Rating: 25kA@480V
✔ Connection: Bolt-On
✔ Functions: LSI – Long Time, Short Time and Instantaneous Trip
✔ Protection: Solid State
✔ Weight: 12

Dimensions
Product Net Width:140 mm
Product Net Height:205 mm
Product Net Depth / Length:103.5 mm
Product Net Weight:3.425 kg
Container Information
Package Level 1 Units:
box 1 piece
Package Level 1 Width:
305 mm
Package Level 1 Height:
285 mm
Package Level 1 Depth / Length:
370 mm
Package Level 1 Gross Weight:
9.7 kg
Package Level 1 EAN:
8056221006477
Additional Information
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Breaking Part
Version:
F
Technical
Electrical Durability:
7000 cycle
60 cycles per hour
Mechanical Durability:
20000 cycle
120 cycles per hour
Number of Poles:
3P
Order Multiple:
1 piece
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 200 kA
(230 V AC) 200 kA
(240 V AC) 200 kA
(380 V AC) 200 kA
(415 V AC) 200 kA
(440 V AC) 180 kA
(500 V AC) 150 kA
(525 V AC) 120 kA
(690 V AC) 100 kA
(250 V DC) 2 Poles in Series 100 kA
Show more
Rated Short-time Withstand Current Low Voltage (Icw):
5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 200 kA
(230 V AC) 200 kA
(240 V AC) 200 kA
(380 V AC) 200 kA
(415 V AC) 200 kA
(440 V AC) 180 kA
(500 V AC) 150 kA
(525 V AC) 120 kA
(690 V AC) 100 kA
(250 V DC) 2 Poles in Series 100 kA
Show more
Rated Uninterrupted Current (Iu):
400 A
Short-Circuit Performance Level:
X
Standards:
IEC60947-2
Sub-type:
XT5
Terminal Connection Type:
Front

C.Breaker Tmax Xt5N 400 Ul/Csa Fixed Three-Pole With Front Terminals And Solid-State Release In Ac Ekip Dip Ls/I R 400

You may also like…