CHF250 Eaton Circuit Breaker 50A 240V 2 Poles

Please call 800-717-6475 to check current stock and pricing.

CHF250 Cutler-Hammer Eaton Type CH 30-amp 2 -Pole Standard trip Circuit Breaker 50A 240V 2-Poles

SKU: CHF250 Category: Brand:

Description

CHF250 Cutler-Hammer Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 50 A, 10 kAIC, Two-pole, 120/240V, CHF, Trip flag, common breaker trip, (1) #14-8 AWG, (2) #14-10 AWG Cu/Al, CHF, Type CH Loadcenters

Manufacturer Part Number: CHF250

Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 50 A, 10 kAIC, Two-pole, 120/240V, CHF, Trip flag, common breaker trip, #10-1/0 AWG Cu/Al, CHF, Type CH Loadcenters

Easy to install
Easy to reset
Best in class performance
Circuit breaker is clearly marked identifying amperage, ratings and the brand
Trip flag visibly indicates breaker status
3/4 in per pole

Specifications

Amperage Rating
50 A
Voltage Rating
120/240V
Actuator
Toggle Handle
Application
Generation, Renewable Energy, Alternative Energy, Conventional Energy, Conventional Energy, Datacenters, CI and Hyper Converged IT Space, Marine Vessels and Equipment
Catalog Description (MFR)
Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 50 A, 10 kAIC, Two-pole, 120/240V, CHF, Trip flag, common breaker trip, #10-1/0 AWG Cu/Al, CHF, Type CH Loadcenters
Catalog_Notes
HACR Rated. Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces. With Trip Indication
Certifications
UL 489
Compliances
HACR Rated
Dimensions
3 IN L x 3/4 IN W x 3 IN H
Interrupt Rating
10 kAIC
Marketing Message (MFR)
Eaton’s residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
Mounting Type
Plug-On
Number Of Poles
2 Pole
Phase
1
Product Feature
AFCI:Advanced electronics to reduce unwanted tripping from non-compliant devices.Standard LED indicates one of seven trip codes to simplify circuit diagnostics.Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history.Branch overvoltage protection for sensitive electronics.Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Eliminates unwanted tripping due to loose pigtail connections, GFCI, GFCI:One pole breakers 15–30A5mA protection per UL943, Improved wireway access, Limited lifetime warranty on all CH products, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., One pole breakers 15–30A, Plug-on neutral, Plug-on neutral: Time savings up to 25% per AFCI and GFCI installationImproved wireway accessEasier troubleshooting due to less wiringEliminates unwanted tripping due to loose pigtail connectionsLimited lifetime warranty on all CH products, Standard LED indicates one of seven trip codes to simplify circuit diagnostics., Time savings up to 25% per AFCI and GFCI installation, Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history
Product Name
Eaton CH thermal magnetic circuit breaker
Product Type
Thermal magnetic circuit breakers
Standard
UL 489,HACR Rated
Trip Type
Trip flag
Type
Type CHF Standard
Wire Size
10 to 1/0 AWG Copper/Aluminum

CHF250

Molded-Case Circuit Breakers

Additional information

Weight 0.01 lbs