Eaton – Cutler Hammer FAZ-C3/2-NA Thermal Magnetic Circuit Breaker, Miniature, C Curve, UL 489, FAZ Series, 3 A, 2 Pole, 48 V
Product Specifications
Product AttributeAttribute ValueSearch
Actuator TypeToggle
ApplicationGeneration – Conventional Energy – Conventional Energy;Other;Generation – Renewable Energy – Alternative Energy;Marine Vessels and Equipment – Marine Vessels and Equipment – Other;Datacenters – IT Space: CI and Hyper Converged
ApprovalsUL 489 ; CSA Std. C22.2 No. 235
CharacteristicC Curve
Current Rating3 A
Height4.13 Inch
Length1.4 Inch
Mounting TypeDIN Rail Mount
Number of Poles2 Pole
SeriesFAZ-NA Series
StandardsUL489
TerminalsStandard terminals
TypeThermal/Magnetic
UPC Code4015081020379
Voltage Rating277 VAC ; 480 VAC
Width2.97 Inch
Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Eatons FAZ-NA DIN rail mountable circuit breaker is designed for use in branch service applications. The FAZ-NA Series is available with B, C and D characteristics in accordance with UL 489, CSA C22.2 No.5, UL 1077, CSA C22.2 No.235 and IEC 60947-2. These devices are CE marked.
Broad Range of Tripping Curves:
B Characteristic for Standard Circuit Protection
C Characteristic for Higher Inrush Currents
D Characteristic for Inductive and Capacitive Loads
Features
Rated Currents Up to 40A
DIN Rail Mount
Suitable for Branch Circuit Device Protection
Current Limiting Design
Fulfill UL489, CSA C22.2 No. 5 and IEC 60947-2
Optional Ring Tongue Connection
Module Width of Only 17.7 mm Per Pole
Reliable and Safe Operation
Captive Screws Cannot Be Lost
Snap-On Accessories
Contact Position Indicator
Finger Proof
Trip-Free Mechanism
Manufacturer: Eaton
MFG Part #: FAZ-C3/2-NA
FAZ-product-guide-eaton
Features
FAZ-NA branch protectors – Fulfill UL 489, CSA C22.2 No.5 and also IEC 60947-2 Standard. For use in applications for which UL 1077 or CSA C22.2 No.235 are also allowed.
Trip-free design. Breaker cannot be defeated by holding the handle in the ON position.
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves.
FAZ-NA branch protectors and supplementary protectors
A color-coded red and green indicator provides immediate visual indication of device status (green for OFF, red for ON) and isolation function.
Easy installation on DIN rail. Module width of only 17.5 mm (per pole).
Power to the circuit breakers can be fed from the line or load side.
Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit.
UL 1053 RCCBs
Thermal-magnetic overcurrent protection.
FAZ supplementary protectors – For use in applications for which UL 1077 or CSA C22.2 No. 235 are required.
Eaton’s FAZ, dual rated UL and IEC circuit breakers are ideal for providing protection in many applications. A current limiting design provides fast short-circuit interruption, offering superior protection by reducing peak let-through current. Superior product quality, tested reliability and safety make Eaton’s UL 1053 Residual Current Circuit Breaker (RCCB) the optimum product for residual current applications. The UL 1053 RCCB circuit breakers provide safety and protection for personnel and equipment.
To save installation time, bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies
Easy installation on DIN rail. Module width of only 17.7 mm (per pole)
Fulfill UL 489, CSA C22.2 No.5 and also IEC 60947-2 Standard. For use in applications for which UL 1077 or CSA C22.2 No.235 are also allowed
Separate version for ring-tongue connection (Type FAZ-RT), terminal screws can be removed (on both sides). Captive screws cannot be lost
Power to the circuit breakers can be fed from the line or load side
A color-coded red/green indicator provides immediate visual indication of device status (green for OFF, red for ON) and isolation function.
Trip-free design. Breaker can not be defeated by holding the handle in the ON position
Three levels of short-circuit protection, Categorized by B, C and D curves
Thermal-magnetic overcurrent protection
Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit
Eaton offers a full range of DIN-Rail miniature circuit breakers up to 40A current rating for feeder and branch circuit protection. Breakers comply with the latest national and international standards including UL 489. Two levels of circuit protection available, one for medium inrush startup currents to provide protection for small transformers, pilot devices, etc., and one with a magnetic range to allow for higher inrush levels during startup usually seen with motors.