W3G800-GV01-91 – EC axial fan – HyBlade Motor: M3G150-NAWeight 57,5 kg,Motor size 150 ,Size 800 mm,Rotor surface Painted black ,Electronics housing material Die-cast aluminum, painted black ,Blade material Sheet aluminum insert, sprayed with PP plastic ,Fan housing material Sheet steel, galvanized and coated with black plastic (RAL 9005) ,Guard grille material Steel, coated with black plastic (RAL 9005) ,Number of blades 5 ,Blade pitch 0° ,Airflow direction V ,Direction of rotation Clockwise, viewed toward rotor ,Degree of protection IP44 ,Insulation class “F” ,Ambient temperature note Occasional start-up at temperatures between -40°C and -25°C is permitted. For continuous operation at ambient temperatures below -25°C (such as refrigeration applications), use must be made of a fan design with special low-temperature bearings. ,Moisture (F) / Environmental (H) protection class H2 ,Max. permitted ambient temp. for motor (transport/storage) +80 °C,Min. permitted ambient temp. for motor (transport/storage) -40 / -55 °C,Installation position Shaft horizontal with cable exit ±45° or rotor at bottom; rotor at top not permissible ,Condensation drainage holes On rotor side ,Mode S1 ,Motor bearing Ball bearing ,Technical features – Output 10 VDC, max. 10 mA – Output 20 VDC, max. 50 mA – Output for slave 0-10 V – Operation and alarm display – Input for sensor 0-10 V or 4-20 mA – External 24 V input (parameter setting) – External release input – Alarm relay – Integrated PID controller – Motor current limitation – PFC, passive – RS-485 MODBUS-RTU – Soft start – Control input 0-10 VDC / PWM – Temperature derating – Thermal overload protection for electronics/motor – Line undervoltage / phase failure detection ,EMC immunity to interference According to EN 61000-6-2 (industrial environment) ,EMC interference emission According to EN 61000-6-4 (industrial environment) ,Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) <= 3,5 mA,Electrical hookup Terminal box ,Motor protection Reverse polarity and locked-rotor protection ,Protection class assignment I; If a protective earth is connected.|The built-in component has several local protection class assignments.|The final protection class is determined by the intended installation. ,Conformity with standards EN 14986; EN 60079-0; EN 60079-1; EN 60079-7; EN 60079-11; EN 61800-5-1 / CE ,Comment on CE Ecodesign Directive 2009/125/EC + Fan Directive (EC) No. 327/2011 does not apply, as the product is specially designed for operation in potentially explosive atmospheres within the meaning of Directive 94/9/EC. ,Approval II 2G / EAC
Datasheet: /ds/W3G800-GT.pdf