background image

                         

 

DATA SHEET

 

Ametherm, Inc

.  3111 N. Deer Run Road #4 Carson City, NV  89701 

Telephone: (800) 808-2434   (775) 884-2434     Fax:  (775) 884-0670

 

www.ametherm.com 

 

Part Number: SL10 50002

 

 

Ordering Different Lead Types:

 

 

 
 

For example: to order an inside kinked lead use part number SL10 50002-

A

 

 

 

     

 
 

 

 
 
 

 
 
 
 

 

Electrical 

Specifications: 

      

 

Mechanical 

Specifications: 

 

 
 
 

Current Resistance 

0.40 Amp 

4.95 

 

0.80 Amp 

1.86 

 

1.20 Amp 

1.03 

 

1.60Amp 

0.69 

 

 

CSA File Number: #CA118061 

 

 

 

 

                   Revision Date: March 19, 2003 

Inside Kinked Leads 

Use 

-A

 after Ametherm’s part # 

Outside Kinked Leads 

Use 

-B

 after Ametherm’s part # 

Resistance @ 25°C  

50.0 

 

±

 25 % 

Max Steady State Current Up to 65

°

1.60 A 

Max Recommended Energy Rating (Joules) 

18.0 J 

Actual Failure Point of Instantaneous Energy (Joules) 

29.0 J 

Body Temperature @ 100% Current Rating 

135°C 

Dissipation Constant 

11.2mW/°C 

Thermal Time Constant 

38 seconds 

Material Type 

“H” 

Max Recommended Capacitance @ 120VAC/240VAC 

1200µF/300µF 

Power Consumption @ Max Current 

1.350 watts 

10.0 

±

 0.5 mm 

3.5 

±

 0.3 mm 

Lead Diameter 

0.5 

±

 0.1 mm 

6.35 

±

 0.6 mm 

9.90 

±

 0.90 mm 

Marking Optional 

6.35 

±

 0.60 mm 

2.82 

±

 0.5 mm 

L

OUTSIDE

KINKED LEADS

S

STRAIGHT

LEADS

B

INSIDE

KINKED LEADS

S

S

D

D

D

C

T