AF30-30-00-12 ABB Contactor 50A 600V 3 Poles

Please call 800-717-6475 to check current stock and pricing.

The ABB AF30-30-00-12 non-reversing 50 Amp, 3-Pole, 600 Volt AC Rated, 48 – 130 Volt AC/DC Coil. AF-Line Series, AF30 Frame, IEC Contactor 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 15 kW / 400 V AC (AC-3) or 20 hp / 480 V UL and switching power circuits up to 50 A (AC-1) or 50 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories

SKU: AF30-30-00-12 Category: Brand:

Description

AF30-30-00-12 ABB IEC Contactor, Non-Reversing, Series: AF Series, 48 to 130 V AC/DC Coil, 50 A Maximum Load Current, 10 hp, 20 hp, 25 hp, 2 hp, 5 hp Coil, 3 Pole, 50/60 Hz Frequency, 9/15/18.5 kW Wattage, 3NO Contact Configuration, 50 A at 690 V Contact, Cable Clamp Connection, AF30 Size, Screw Terminal, IP20 Enclosure, 300 Cycles Operating Cycles, -60 to 80 deg C Operating, 45 mm W x 86 mm D x 86 mm H Dimensions

Primarily for controlling single and three phase motors and switching power circuits 3 poles 50 amperes non-reversing across the line contactor with 48-130V AC/DC coil and no auxiliary contacts. 86 millimiters depth x 86 millimiters height x 45 millimiters width.

Number of Main Contacts NO: 3
Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 50(690 V) 60 °C 42 A, (690 V) 70 °C 37
Rated Operational Current AC-3 (Ie): (415 V) 60 °C 32 A, (440 V) 60 °C 32 A, (500 V) 60 °C 28 A, (690 V) 60 °C 21 A, (380 / 400 V) 60 °C 32 A, (220 / 230 / 240 V) 60 °C 33 A
Rated Operational Power AC-3 (Pe): (400 V) 15 kW, (415 V) 15 kW, (440 V) 18.5 kW, (500 V) 18.5 kW, (690 V) 18.5 kW, (380 / 400 V) 15 kW, (220 / 230 / 240 V) 9 kW
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A, for 1 s -empty- A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 1200 cycles per hour
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 6 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 48 … 130 V50 Hz / 60 Hz 48 … 130 V, 60 Hz 48 … 130 VDC Operation 48 … 130 V
Operate Time: Between Coil De-energization and NC Contact Closing 13 … 98 ms, Between Coil De-energization and NO Contact Opening 11 … 95 ms, Between Coil Energization and NC Contact Opening 38 … 90 ms, Between Coil Energization and NO Contact Closing 40 … 95 ms
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 1.5 … 10 mm², Flexible with Insulated Ferrule 1x 1.5 … 10 mm², Flexible with Insulated Ferrule 2x 1.5 … 4 mm², Rigid 1/2x 2.5 … 10 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 … 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm², Rigid 1/2x 1 … 2.5 mm²
Wire Stripping Length: Control Circuit 10 mm, Main Circuit 14 mm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type: Screw Terminals
Specs: AF30-30-00-12