Westermo Viper Series EN 50155 Unmanaged 8 or 12-Port Ethernet Switch

Please call 800-717-6475 to check current stock and pricing.

Westermo Viper Series EN 50155 Unmanaged 8 or 12-Port Ethernet Switches, M12 Connectors, 24-110 VDC Powered, -40 to +70 deg. C

SKU: Viper Unmanaged Series Category: Brand:

Description

Westermo Viper Unmanaged Series Westermo Viper Series EN 50155 Unmanaged 8 or 12-Port Ethernet Switches, M12 Connectors, 24-110 VDC Powered, -40 to +70 deg. C
The Viper rugged unmanaged Ethernet switches are designed for applications with severe operating conditions and extreme environments. The switches meets the EN 50155 standard for electronic equipment used in railway applications. The super slim and extra robust housing is sealed to IP65 and together with an MTBF (Mean Time Between Failure) calculated to more than a 100 years make these units ideal for situations where mechanical stress, moisture, condensation, dirt or continuous vibrations could adversely affect the function of standard Ethernet switches.

The units are well prepared for use in harsh industrial environments. The IP65 sealed metal cases and rugged M12 front connectors of the unit makes it robust and allows temperatures from -40 to +70 deg. C (-40 to +158 deg. F).

There are no sensitive or fragile components, hardening the product against shock and vibration making these units suitable for rolling stock usage. The power supply operates over a wide input range from 24 to 110 VDC ±40%.
Features and Benefits

Compact basic rail-approved Ethernet switch
Fully EN 50155 compliant
Single model 24 – 110 VDC power range
8 or 12 x 100 Mbit/s Ethernet ports
Externally tested and verified to EN 50155
Surge resistance and isolation
Magnetic field immunity & conducted emission
Shock and vibration
Designed for long life and extreme operational environments
IP65 anti-condensation GORE-TEX® membrane
Ambient temperature -40°C (-40°F) to +70°C (+158°F)
Integrated M12 threading and extremely high MTBF, 1,289,000 hours
Design and production testing to match requirements for train control
Post production testing exceeding EN 50155 mandatory requirement
Isolation test on all units
Manufactured according to IPC-A-610D class2