Description
RED00202 Redundant O-Ring Modul 1000W DIN-Rail. N+1 Power Redundant Module DIN-Rail TS35mm
- N+1 Power Redundant Module DIN-Rail TS35mm
- 2x 1000W Inputs, 1x 1000W Output
- Lower voltage margin adjustable
- Input & Output = floating
- Decoupling Diode = fast Schottky
- Voltage Drop typ. 500mV
| Model | RED00202A |
| Maxmum Current | Up to 2x50A per connection |
| V1in/V2in | + 12 up to 28Vdc (36V) 2x 50A |
| LED | Control-LED |
| Monitoring Relay | Integrated (floating) |
| Cooling | Natural convection |
| Efficiency | > 97% (24V) |
| Load connection | Screw-type terminal |
| Alarm contact | Screw-type terminal plug-in |
| Ambient temperature | -20°C … +70°C |
| Dimensions WxHxD | 62 x 130 x 115mm |
| Special Features | High reliable |
| Compact outline | |
| Reverse polarity protection | |
| Alarm monitoring loss of U1/U2 |
Manufacturer:Camtec
Datasheet:Camtec_HPV04801_E0613F.pdf
The HPV power supply series realizes very high-
power efficiency in a space-saving housing. Latest
generation electrical devices relate to the high
reliability of all CAMTEC products. The CAMTEC
philosophy is, to employ 125°C low ESR ultra
long-life capacitors where expedient to achieve a
superior lifetime of the product. The HPV power
supply is made for high reliable and demanding
industrial applications, railway, infrastructure,
professional machine building, printing machines
and complex dc-drive up to precision piezo drives.
DC-ok Power Good Relay
The PG Relay connection indicates over
temperature, low DC-voltage at the output and low
AC supply voltage at the input.
Galvanic Isolation
The power supply is galvanic isolated between the
input and the output. All features like the Power
Good Relay are connected to the DC power
outputs.
Thermal shutdown
The HPV is featured with a thermal overload shut
down and auto recovery behaviour.
Over Voltage Protection
Ticker mode and auto recovery
hort Circuit Protection
A continuous short circuit does not cause damage to the
power supply. The HPV delivers constant current and 0
output voltage. It recovers automatically after the short
circuit is released.
Open Circuit Protection
The HPV series is continuously open circuit protected.
The device delivers a stable output voltage and no
current. If a load is immediately connected to the device,
the power supply stabilizes within 1ms. It does not
overshoot the output voltage.
Power Up Ramp
The devices have a soft start ramp when powering up.
The device does not either overshoot the voltage nor
does the output flutter – independent if a load is
connected or not.
Current Voltage Chart, CV & CC mode
The HPV series provides a perfect current voltage chart.
It has no fold back or other abnormalities. The output
voltage can drop down to zero volts when the power
supply is overloaded. The unit delivers a stable and
constant current to the outputs.